585836101 Ignition Module Coil for Husqvarna and Ryobi Handheld Blowers

Key Features

  • Precision Electronic Ignition: Engineered to provide a consistent, high-intensity spark across the entire RPM range, ensuring reliable starting and smooth engine performance.
  • Optimized Ignition Mapping: Specifically calibrated for small-displacement 2-stroke blower engines, improving fuel efficiency and reducing emissions during high-speed operation.
  • Weather-Shielded Encapsulation: The internal circuitry is fully potted in high-grade, heat-resistant epoxy to protect against vibration, moisture, and debris common in lawn care environments.
  • Reinforced Spark Plug Lead: Features a high-tension wire with a durable silicone boot designed to resist cracking and electrical "arching" against the engine cylinder.
  • Direct Bolt-On Fitment: Designed to the exact mounting specifications of the original factory module, facilitating a straightforward "drop-in" replacement without modifications.

Replaces / Cross-Reference Part Numbers

  • Husqvarna: 585836101, 545108101, 5451 08 101
  • Homelite / Ryobi: 300953003, 300953001, 984883001, 984882001
  • Other: 850108101

Compatibility & Fitment

This ignition coil is a universal replacement for several popular handheld blower platforms. Key compatible models include:

  • Husqvarna: 125B, 125BVX, 125BX (Standard and E-series models).
  • Ryobi: Fits various 25cc and 26cc handheld blowers (e.g., RY08510, RY08544, RY08548).
  • Homelite: Compatible with many 26cc "Blower/Vac" models (e.g., UT08514, UT08544, UT08546).
  • Note: Always verify your original coil's mounting hole spacing and wire orientation, as these models occasionally used different engine suppliers.

When to Replace

  • No Spark Condition: The most common failure; the engine will not start despite having fresh fuel and a clean spark plug.
  • Stalling When Hot: The blower runs perfectly for 5–10 minutes but dies as the engine reaches operating temperature and won't restart until cooled (thermal failure).
  • Misfiring or "Stuttering": The engine hesitates at full throttle or has an inconsistent idle, indicating the coil is struggling to maintain a steady pulse.
  • Visible Insulation Damage: The spark plug wire is frayed, melted, or showing signs of being chewed by rodents, leading to a grounded ignition circuit.
  • Intermittent Kill Switch Issues: If the engine refuses to shut off or dies unexpectedly, the kill switch terminal on the coil may be shorting internally.

Installation & Timing Tips

  • The "Business Card" Gap: To ensure the strongest spark, the air gap between the coil legs and the flywheel magnets should be approximately 0.010" to 0.012". Use a standard business card as a gauge during installation.
  • Check the Ground Path: Ensure the mounting surfaces on the engine block and the coil legs are free of rust and oil. The coil grounds through its mounting bolts; a weak ground equals a weak spark.
  • Kill Switch Wiring: Be careful when attaching the small spade terminal for the stop wire. If this wire is pinched against the metal housing, the engine will never start.
  • Flywheel Magnet Cleanup: While the starter cover is off, use a rag to wipe metal shavings or sap off the flywheel magnets to ensure the strongest possible magnetic induction.
  • Spark Plug Health: It is highly recommended to install a fresh NGK BPMR7A (or equivalent) spark plug when replacing the coil to ensure the new module isn't stressed by a fouled plug.
$9.09

Original: $25.96

-65%
[Lifetime Warranty] 585836101 Handheld Blower Ignition Module Coil - Compatible with Husqvarna 125B 125BVX 125BX Homelite Ryobi 300953003 300953001 984883001 984882001 - Replaces 545108101 545108101

$25.96

$9.09

Product Information

Shipping & Returns

Description

585836101 Ignition Module Coil for Husqvarna and Ryobi Handheld Blowers

Key Features

  • Precision Electronic Ignition: Engineered to provide a consistent, high-intensity spark across the entire RPM range, ensuring reliable starting and smooth engine performance.
  • Optimized Ignition Mapping: Specifically calibrated for small-displacement 2-stroke blower engines, improving fuel efficiency and reducing emissions during high-speed operation.
  • Weather-Shielded Encapsulation: The internal circuitry is fully potted in high-grade, heat-resistant epoxy to protect against vibration, moisture, and debris common in lawn care environments.
  • Reinforced Spark Plug Lead: Features a high-tension wire with a durable silicone boot designed to resist cracking and electrical "arching" against the engine cylinder.
  • Direct Bolt-On Fitment: Designed to the exact mounting specifications of the original factory module, facilitating a straightforward "drop-in" replacement without modifications.

Replaces / Cross-Reference Part Numbers

  • Husqvarna: 585836101, 545108101, 5451 08 101
  • Homelite / Ryobi: 300953003, 300953001, 984883001, 984882001
  • Other: 850108101

Compatibility & Fitment

This ignition coil is a universal replacement for several popular handheld blower platforms. Key compatible models include:

  • Husqvarna: 125B, 125BVX, 125BX (Standard and E-series models).
  • Ryobi: Fits various 25cc and 26cc handheld blowers (e.g., RY08510, RY08544, RY08548).
  • Homelite: Compatible with many 26cc "Blower/Vac" models (e.g., UT08514, UT08544, UT08546).
  • Note: Always verify your original coil's mounting hole spacing and wire orientation, as these models occasionally used different engine suppliers.

When to Replace

  • No Spark Condition: The most common failure; the engine will not start despite having fresh fuel and a clean spark plug.
  • Stalling When Hot: The blower runs perfectly for 5–10 minutes but dies as the engine reaches operating temperature and won't restart until cooled (thermal failure).
  • Misfiring or "Stuttering": The engine hesitates at full throttle or has an inconsistent idle, indicating the coil is struggling to maintain a steady pulse.
  • Visible Insulation Damage: The spark plug wire is frayed, melted, or showing signs of being chewed by rodents, leading to a grounded ignition circuit.
  • Intermittent Kill Switch Issues: If the engine refuses to shut off or dies unexpectedly, the kill switch terminal on the coil may be shorting internally.

Installation & Timing Tips

  • The "Business Card" Gap: To ensure the strongest spark, the air gap between the coil legs and the flywheel magnets should be approximately 0.010" to 0.012". Use a standard business card as a gauge during installation.
  • Check the Ground Path: Ensure the mounting surfaces on the engine block and the coil legs are free of rust and oil. The coil grounds through its mounting bolts; a weak ground equals a weak spark.
  • Kill Switch Wiring: Be careful when attaching the small spade terminal for the stop wire. If this wire is pinched against the metal housing, the engine will never start.
  • Flywheel Magnet Cleanup: While the starter cover is off, use a rag to wipe metal shavings or sap off the flywheel magnets to ensure the strongest possible magnetic induction.
  • Spark Plug Health: It is highly recommended to install a fresh NGK BPMR7A (or equivalent) spark plug when replacing the coil to ensure the new module isn't stressed by a fouled plug.

You may also like

NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] T35 Bump Knob Replacement 537185801 - Compatible with Husqvarna T35 Trimmer Head (2003-05, 2005-01, 2007-04) - Pack of 4

$20.16

NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 20-inch Chainsaw Chain 3/8" LP Pitch 0.050" Gauge 72 Drive Links - Compatible with Stihl MS029 036 039 391 310 311 Husqvarna 455 Rancher 460 55 257 261 359 362XP 272XP 555455 H80 - Pack of 3

$32.96

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 18-inch Chainsaw Chain 3/8" LP Pitch 0.050" Gauge 62 Drive Links - Compatible with Craftsman CS1803 Ego CS1804 CS1800 Poulan 2025 Kobalt KCS 180B-06 Echo CS-280 Greenworks S62 - Pack of 3

$26.68

$9.34

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 16-inch Chainsaw Chain 3/8" LP Pitch 0.050" Gauge 56 Drive Links - Pack of 3

$21.25

$7.44

NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 946-0897 Snow Blower Auger Clutch Cable

$12.59

NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 699334 Starter Handle and Rope

$15.74

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 52100100 Snow Blower Shear Pins and Nuts - Pack of 10

$18.83

$6.59

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] PB-580T A226000032 Air Filter - Compatible with Echo Leaf Blower PB755ST PB500T PB580H PB403 PB403H PB403T PB413H PB413T PB500H PB603 PB611 PB620 PB620ST PB650 PB650H PB650T A226000031 - Pack of 10

$23.54

$8.24

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] A051000960 A051000961 Recoil Starter Pull Start - Compatible with Echo ES-250 PB-250 PB-250LN ES-252 PB-252 25.4cc Blowers

$21.25

$7.44

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 490-241-0002 Snowblower Starter Handle Rope

$15.74

$5.51

-65%NEW
Thumbnail 1Thumbnail 2

[Lifetime Warranty] 303160355P 303160355 Snow Blower Shear Pins and Nuts - Pack of 4

$14.12

$4.94